The skin effect refers to the phenomenon of uneven distribution of alternating current within a conductor: the current density decreases exponentially from the conductor’s surface inwards, with the central region almost no longer carrying current. This effect makes the conductor’s AC resistance higher than its DC resistance, and it deteriorates sharply with increasing frequency.

For round conductors, the effect of the skin effect is relatively straightforward—a ring-shaped conductive region forms inside the conductor, which can be estimated using the ratio of the equivalent radius to the skin depth. However, flat enamel-coated copper wires have a rectangular cross-section, resulting in a completely different current distribution: each of the four surfaces forms an independent shallow conductive band, and the conductivity is dominated by the width-to-thickness ratio, rather than the cross-sectional area. This difference fundamentally alters the high-frequency performance of flat wires compared to round wires, and even makes flat wires superior to round wires in certain frequency bands.

This paper takes the skin depth model of the copper conductor as the starting point for analysis, and systematically elaborates on the current distribution characteristics of the flat wire cross section at high frequencies, the loss asymmetry in the thickness and width directions, the coupling effect of inter-turn and interlayer proximity effect, and the dielectric loss of enamel coating, as well as the applicable boundaries of flat wire and Litz wire. It provides quantifiable selection basis for the design of high-frequency inductors, switching power supply transformers, induction heating, wireless charging, and traction motor drive winding.

 

Skin Depth Model and Applicability to Flat Wire Cross-Sections

Physical Definition and Calculation of Skin Depth

The skin depth δ is the depth at which the current density decays from the surface to 1/e (approximately 36.8%) of the surface value, and is calculated as follows:

δ = √(2 / ωμσ) = 1 / √(πfμσ)

In the formula: δ is the skin depth (meters); f is the frequency (Hertz); μ is the permeability (henries/meter); σ is the conductivity (Siemens/meter). The non-magnetic nature of copper results in a relative permeability μr ≈ 1, approximating the vacuum permeability μ0 = 4π × 10⁻⁷ Henry/meter; at 20°C, the conductivity of copper σ ≈ 5.8 × 10⁷ Siemens/meter.

Therefore, the commonly used estimation formula in engineering can be obtained: δ(copper) ≈ 66 / √f mm (f is in kilohertz).

The skin depth of the copper conductor varies with frequency as follows:

Frequency Skin Depth δ Frequency Skin Depth δ
50 Hz 9.3 mm 100 kHz 0.21 mm
60 Hz 8.5 mm 500 kHz 0.093 mm
1 kHz 2.1 mm 1 MHz 0.066 mm
10 kHz 0.66 mm 10 MHz 0.021 mm
100 kHz 0.21 mm 1 GHz 0.0021 mm

The skin depth is inversely proportional to the square root of the frequency; for every order of magnitude increase in frequency, the skin depth decreases by approximately 0.316 times. This scaling relationship forms the basis for all subsequent loss analyses.

Fundamental Difference in Conductive Regions Between Round and Flat Wire

The effective conductive region of a circular conductor under the skin effect is a ring around its axis, and its equivalent conductive area can be estimated by the ratio of the equivalent radius to the skin depth. When the conductor radius is much larger than the skin depth, the effective conductive area is approximately 2πrδ.

The conductive area distribution is completely different in a rectangular cross-section. A flat wire has two geometric dimensions: two wide facets (large area) in the width direction and two narrow facets (small area) in the thickness direction. Current preferentially flows along the wide facets because the ratio of the perimeter to the cross-sectional area of ​​the wide facet is larger; the equivalent conductive area is approximately:

A_eff ≈ 2δ(w + t) – 4δ²

In the formula, w is the width of the flat wire and t is the thickness of the flat wire. When the thickness t is much greater than the skin depth and the width w is also much greater than the skin depth, the contribution in the thickness direction degenerates into a constant term 4δ², and the main contribution comes from the width direction: at this time, thickening the flat wire has almost no improvement on the high-frequency resistance, while widening it is still effective.

Flat Wire Cross-Section Operating Frequency Skin Depth High-Frequency Effective Conductive Region Key Criterion
10 mm wide × 1.0 mm thick 20 kHz 0.47 mm Mainly two wide-face layers Thickness already exceeds δ, limited contribution in the thickness direction
10 mm wide × 1.0 mm thick 100 kHz 0.21 mm Shallow wide-face layer only Thickening is ineffective, widening is required
10 mm wide × 2.0 mm thick 100 kHz 0.21 mm Shallow wide-face layer only Doubling thickness leaves AC resistance almost unchanged
10 mm wide × 1.0 mm thick 1 MHz 0.066 mm Extremely shallow wide-face layer Copper utilization falls to single-digit percentage
30 mm wide × 1.0 mm thick 1 MHz 0.066 mm Extremely shallow wide-face layer Widening threefold cuts AC resistance to about one third

This geometric characteristic is confirmed in authoritative engineering manuals. Section 5.2.4.2 of the U.S. Naval Facilities Engineering Command MIL-HDBK-419A explicitly states that at frequencies where the skin effect begins to appear, when the width-to-thickness ratio exceeds approximately 2:1, the resistivity of a flat rectangular conductor will be lower than that of a solid circular conductor of the same cross-sectional area. This 2:1 criterion is the most practical empirical starting point for high-frequency selection of flat wires.

Loss Asymmetry Between the Thickness and Width Directions

This is the most valuable conclusion regarding flat wire in high-frequency applications.

When the skin depth is much smaller than the thickness of the flat wire, the current in the thickness direction completely decays after several times the skin depth. Increasing the thickness only increases weight, slot volume, and DC resistance, without improving AC resistance. In this case, there is only one effective design approach—increasing the width.

It is important to note that the benefits of widening the skin at high frequencies also diminish. When the skin depth is much smaller than the cross-sectional size, the equivalent conductive area approaches the width linear term in 4δ(w+t), and the resistance is inversely proportional to the width. However, the ratio relative to DC resistance has stabilized, and the marginal benefit of further widening continues to decline.


Amplification of Proximity Effect in Flat Wire Windings

Physical Mechanism of the Proximity Effect

The skin effect is the result of a conductor interacting with its own magnetic field, while the proximity effect is the redistribution of current distribution by the magnetic fields of neighboring conductors. When the currents in adjacent conductors are in opposite directions, their respective alternating magnetic fields induce additional eddy currents within each other, causing the current to further concentrate on the opposing surfaces. These two effects are superimposed, not substituted for each other.

This effect is particularly pronounced in flat wire winding: when flat wires are arranged in a tight rectangular array within a slot or between layers, the magnetic coupling coefficient between conductors approaches the geometric limit.

Dowell Criterion for Layered Loss

The proximity effect loss of the winding is calculated using Dowell’s formula, and the loss coefficient increases quadratically with the number of effective conductive layers. The effective number of layers is not the physical number of layers, but rather the number of conductor layers perpendicular to the direction of the winding magnetic field.

Taking the same volume of winding as an example:

Winding Structure Effective Conductive Layers Relative Loss at 10 kHz Interpretation
5 mm × 5 mm solid busbar 1 1.0 (baseline) Single layer, no inter-layer proximity loss
Matrix of 25 pieces 1 mm × 1 mm 5 about 25 Layering gains are offset by proximity loss
Matrix of 100 pieces 0.5 mm × 0.5 mm 10 about 100 Only turns positive once the strand diameter is small enough

This criterion provides a clear engineering conclusion: splitting a flat wire into thinner strands is not unconditionally effective. Only when the thickness of a single strand is significantly less than the skin depth can the benefits of reducing the skin effect outweigh the losses from the proximity effects.

Proximity Effect Sensitive Points in Flat Wire Windings

High-frequency design of flat wires requires targeted control of the following geometric features:

Inter-turn arrangement within a slot: adjacent turns within the same slot face each other, the magnetic field is most concentrated in the two inter-turns, and the inter-turn current is concentrated towards the opposite face.

Interlayer positional offset—In multi-layer flat wire winding, the innermost layer is completely shielded by the magnetic field of the outer layer, and its proximity effect loss is significantly higher than that of the outer layer.

End transposition—the flat wire has a slanted slot at the end, resulting in an asymmetrical conductor path and potentially causing local magnetic flux imbalance.

Geometric partitioning—rotating the wide face of a flat conductor 90° along the direction of the magnetic field so that the current direction is orthogonal to the winding magnetic field can significantly reduce the proximity effect loss. This is the principle of planar transformer transposition and Robel transposition.


Coupling of Enamel Dielectric Loss with the Skin Effect

Enamel Dielectric Loss at High Frequencies

The skin effect focuses on conductor loss, but flat enamel-coated copper wires also have an insulation layer. Above 100 kHz, the dielectric loss factor (tan δ) of the enamel coating begins to contribute substantially to the total loss.

Dielectric loss characteristics of common enamel coating systems:

Enamel System Long-Term Heat Resistance High-Frequency Dielectric Loss Behavior High-Frequency Suitability
Polyurethane (UEW) 130°C Low tan δ, solderable Preferred for medium and high frequency solderable windings
Polyester (PEW) 155°C Moderate Acceptable for conventional high-frequency applications
Polyesterimide (EIW) 180°C Slightly higher than PEW For cases requiring greater temperature-rise margin
Polyamide-imide (AIW) 200–220°C Higher, but best mechanical abrasion resistance For high-frequency applications requiring winding strength as well

The role of AIW (enamel coating) in high-frequency applications deserves separate explanation: while its dielectric loss is not the lowest, its mechanical abrasion resistance is significantly better than that of polyester and polyester imide, and its softening breakdown temperature is typically above 330°C to 350°C. During flat wire winding, the stress concentration at the corners of the enamel coating is most severe under repeated bending and slot friction; in this case, the integrity of the enamel coating may have a greater impact on reliability than the dielectric loss itself.

Dual Role of Enamel Thickness on High-Frequency Performance

The thickness of the enamel coating has a dual effect at high frequencies: dielectric loss increases with increasing enamel coating thickness, thicker enamel coatings store more energy under the same electric field, and dielectric loss is amplified according to the E² relationship; while the breakdown voltage increases with increasing thickness, providing a greater inter-turn insulation margin for winding.

Therefore, the selection of enamel coating thickness for high-frequency flat wires is not simply a matter of insulation margin; a balance must be struck between dielectric loss and breakdown margin. In engineering practice, priority should be given to ensuring that the inter-turn voltage margin does not exceed the rated breakdown voltage of the enamel coating. Only under this premise should a thinner enamel coating grade be selected to control dielectric loss.

Amplification of Enamel Stress by Flat Geometry

During the winding and slotting process of flat wire, the bending strain at the corners is the greatest. The tensile stress at the corners of the enamel coating exceeds that on the straight edges, which is significantly different from the uniform strain along the circumference of round wire. The high-frequency temperature rise caused by the skin effect further accelerates the thermal aging of the enamel coating, resulting in the superposition of stress cracks and thermal aging damage at the corners.

When selecting high-frequency coatings, the mechanical abrasion resistance and thermal shock resistance of the enamel type, like the skin depth, are indispensable prerequisites.


Applicability Boundaries of Flat Wire and Litz Wire at High Frequency

Essential Difference Between Two High-Frequency Winding Strategies

There are two ways to deal with the skin effect and high-frequency winding.

Flattening the path—by increasing the ratio of conductor width to perimeter, current flows in a shallow manner over a wide surface; essentially, it is an adjustment of spatial geometry.

The thinning approach involves splitting the conductor into multiple independent insulated strands and repositioning them for weaving, so that each strand is located at any radial position in the envelope layer. Essentially, it is a reorganization of the conductor structure.

The two methods differ fundamentally in their loss characteristics. The flat wire method limits the number of layers with a proximity effect to the physical number of layers, resulting in a simple structure, high winding efficiency, and reliable termination. The Litz wire method eliminates the proximity effect between strands through transposition, but in actual engineering, termination quality often becomes the decisive factor—incomplete solder wetting can cause some strands to remain unconnected, subtly reducing the equivalent conductor cross-section.

Criteria for Transposition and Strand Selection

The selection of the diameter of the thin strand must simultaneously satisfy both the skin effect and the proximity effect:

When the diameter of a single strand d ≤ 2δ, the increase in AC resistance due to the skin effect is approximately 8%; when d = δ, it is less than 1%. This is the upper limit.

When the dominant effect is the proximity effect rather than the skin effect, the actual value needs to be further lowered to d ≈ 0.5δ.

Based on this criterion, the reference value for the diameter of the thin strand of the copper conductor is:

Operating Frequency Skin Depth Maximum Recommended Strand Diameter Common AWG Range
10 kHz 0.66 mm 1.32 mm AWG 30 and finer
100 kHz 0.21 mm 0.42 mm AWG 26–32
500 kHz 0.093 mm 0.19 mm AWG 32–38
1 MHz 0.066 mm 0.13 mm AWG 34–40

Application Scenario Selection

The applicable boundaries of flat wire and Litz wire can be defined according to the combination of conductor cross-sectional dimensions and operating frequency:

Scenario Conductor Cross-Section Characteristics Operating Frequency Recommended Solution Key Rationale
Switching power supply transformer Rectangular flat wire, few layers 20–500 kHz Flat wire Controllable proximity layer count, reliable termination
Planar transformer Copper foil or ultra-flat wire 100 kHz–2 MHz Ultra-flat wire Geometric partitioning suppresses the proximity effect
Filter inductor Flat or rectangular winding 50–500 kHz Flat wire Low loss, high slot fill factor
Induction heating coil Flat wire or copper bar 25–100 kHz Flat wire Exploits shallow skin heating of the workpiece
Wireless charging coil Litz or spiral flat wire 100–300 kHz Litz wire Flexible winding and proximity effect suppression
RF resonant cavity Copper bar or silver-plated conductor Above 1 MHz Copper bar / plated conductor Skin depth enters the micrometre range
Traction motor drive Flat wire 1–20 kHz Flat wire Slot fill factor takes priority, skin effect has limited influence

Here’s an easily overlooked fact: in the 1 kHz to 20 kHz switching power supply and traction drive frequency band, the flat wire thickness is generally greater than the skin depth in this band. The difference between AC resistance and DC resistance is typically on the order of a few percent to a dozen percent, far lower than some designers’ expectations for high-frequency losses. At this point, the dominant factors determining winding temperature rise are usually the copper fill factor, number of turns, and heat dissipation conditions, rather than the skin effect. The skin effect should truly be the primary constraint for high-frequency magnetic components above 100 kHz.


Engineering Calculation and Verification of AC Resistance

Conversion Between AC Resistance and DC Resistance

The AC resistance of a flat wire winding can be estimated using the following formula:

R_ac = R_dc × (k_skin + k_proximity)

Where k_skin is the skin effect coefficient and k_proximity is the proximity effect coefficient. For single-layer flat wire winding, the proximity effect term can be ignored or only the end contribution is considered; when the conductor thickness is twice the skin depth, the increase in AC resistance caused by the skin effect is about 2%, while in multi-layer winding, the proximity effect can increase this ratio to 28 times.

This comparison illustrates the distribution of engineering concerns: in the low-frequency band, there is no need to pay material costs for the skin effect, while in high-frequency multilayer winding, the contribution of the proximity effect far exceeds the skin effect itself, and winding geometry design takes precedence over material selection.

Verification Methods

The actual impact of the skin effect and the proximity effect can be verified in the following ways:

According to IEC 60851-3, measure the AC resistance of the wind at a specified frequency and compare it with the DC resistance to obtain the resistance ratio.

The AC resistance of a single conductor and the AC resistance of the entire wind section are measured separately using segmented measurements. The difference is the contribution of interlayer and inter-turn proximity effect.

The design retains the alignment of the test terminals, allowing the same winding to be measured repeatedly at multiple frequency points, avoiding extrapolation from a limited number of frequency points.

High-Frequency Differences Between Copper and Aluminum Conductors

The selection of conductor materials at high frequencies needs to be re-evaluated. Aluminum’s resistance is approximately 1.6 times that of copper, but the skin depth, calculated as the inverse square root of conductivity, is: δ(aluminum)/δ(copper) = √(σcopper/σaluminum) ≈ √(3.5×10⁷ / 5.8×10⁷) ≈ 0.78. In other words, at the same frequency, aluminum’s skin depth is about 78% that of copper, slightly deeper, resulting in a more uniform current distribution. This slight advantage in skin depth cannot offset aluminum’s disadvantage in resistance—in the conventional high-frequency magnetic component band (100 kHz–1 MHz), copper remains the dominant conductor material.

The high-frequency performance of copper clad aluminum wire depends on the ratio of the copper layer thickness to the skin depth. At low frequencies, the copper layer and the aluminum core conduct electricity together. As the frequency increases and the skin depth becomes less than the copper layer thickness, almost all the current is concentrated within the copper layer, resulting in high-frequency performance close to that of pure copper. Conversely, if the copper layer thickness is much smaller than the skin depth, the current will penetrate the copper layer and enter the aluminum core, significantly deteriorating the high-frequency resistance.


Manufacturing and Supply Chain Matching Requirements for Magnet Wire

Impact of Dimensional Tolerance on High-Frequency Performance

The conductor arrangement in high-frequency flat wires relies on precise geometric control. NEMA MW 1000-2018 and IEC 60317 series standards specify tolerance zones for the width and thickness of rectangular conductors, but tolerances affect more than just the slot fill factor.

When the thickness of the flat wire approaches several times the skin depth, negative thickness tolerance directly reduces the effective conductive area. Systematic deviations in the thickness of each turn in the winding will lead to impedance mismatch in the parallel path, resulting in additional circulating current losses. Therefore, when procuring high-frequency flat wire, in addition to standard width and thickness tolerances, it is also necessary to specify the consistency requirements for the enamel coating thickness.

Matching Enamel Type and Thermal Class

Temperature rise control in high-frequency operating environments requires the enamel coating to have sufficient thermal margin. Commonly used thermal class systems include:

Enamel System Nominal Class Short-Time Heat Resistance Recommended Maximum Temperature Rise
Polyurethane (UEW) 130°C 180°C 60 K
Polyester (PEW) 155°C 200°C 80 K
Polyesterimide (EIW) 180°C 220°C 100 K
Polyamide-imide (AIW) 200–220°C 260°C 120 K

High-frequency winding temperature rise margin must be considered in conjunction with the increase in skin effect losses. If the additional losses caused by the skin effect already account for a significant proportion of the total winding losses, the remaining temperature rise margin will be compressed, and the enamel type must be upgraded.

Conductor Specification and Supply Capability

The key control points affecting high-frequency performance in the manufacturing process are concentrated in three areas:

Conductor fillet radius – The sharp edges and corners of rectangular conductors are prone to mechanical damage during winding, and standardized fillet radii are the basis for the integrity of the coating.

enamel coating uniformity – high frequency winding requires enamel coating to have consistent resistance along its entire length; local thinning will become a weak point in the withstand voltage.

Corner coverage – The four corners are the most stress-bearing areas of the enamel coating, and the thickness of the coating and the bonding strength determine the actual pressure resistance.


Selection Decision Framework for High-Frequency Flat Wire Windings

Five-Step Selection Process

The selection of high-frequency flat (enamel coating) copper wire can be carried out according to the following procedure.

The first step is to confirm the operating frequency and loss budget. Define the operating frequency, winding current, allowable temperature rise, and target efficiency. Losses should first be estimated based on DC resistance. If the estimate meets the target, it indicates that the skin effect is not a dominant constraint in this frequency band, and complex geometric design is unnecessary.

The second step is to calculate the skin depth and verify the conductor thickness. Calculate the skin depth using δ = 66/√f (kHz) and compare it with the candidate flat wire thickness. If the thickness is less than 2δ, the thickening scheme needs to be re-evaluated, and instead, the wire should be widened.

The third step is to verify the proximity effect and the number of layers. Check the effective number of conductive layers according to the Dowell criterion, and determine whether the winding geometry can employ suppression methods such as segmented transposition or wide-area orthogonal arrangement. For multi-layer flat wire winding, the upper limit of the number of layers and the flux linkage conditions for each layer must be clearly defined.

Step 4: Determine the enamel type and thickness grade. A balance must be struck between breakdown voltage margin, dielectric loss, and mechanical abrasion resistance. In high-frequency applications, cost advantages should not be gained by reducing the enamel type, as enamel coating failure is irreversible.

Step 5: Clarify the verification methods and acceptance criteria. Determine the test frequency and acceptance limits for AC resistance according to IEC 60851-3, and incorporate the AC resistance ratio into the incoming material acceptance process.

Selection Decision Matrix

Application Condition Conductor Solution Enamel Solution Winding Structure Focus Verification Focus
Frequency below 20 kHz Standard flat wire, thickness priority PEW or EIW High slot fill factor priority DC resistance and temperature rise
20–100 kHz Flat wire, balance width and thickness PEW or EIW Control parallel turn length AC resistance ratio
100 kHz–1 MHz Flat wire, width takes priority over thickness EIW or AIW Minimize layer count, shorten end turns Proximity effect loss distribution
Above 1 MHz Ultra-flat wire or copper bar AIW Geometric partitioning, width orthogonal to the magnetic field Dielectric loss and breakdown margin
Space constrained and flexible required Litz wire UEW or PEW Transposed weaving, full wetting at termination Termination resistance consistency

Avoiding Common Design Pitfalls

Misconception 1: The belief that higher frequencies necessarily require thinner wires. While higher frequencies do reduce skin depth, when the number of winding layers is limited by slot space, thinning can actually worsen losses due to the proximity effect. Flat wire solutions address this through widening and layer reduction, while Litz wire solutions address it through thinning and transposition—two parallel paths.

Misconception 2: Using DC resistance as the acceptance criterion for high-frequency winding. Passing the DC resistance test does not guarantee that the AC operating conditions are acceptable; an AC resistance test must be conducted as a supplement.

Misconception 3: The high-frequency performance of flat wire is superior to that of round wire. This conclusion only holds true when the thickness of the flat wire is close to or less than the skin depth. In the common switching power supply frequency band from 1 kHz to 20 kHz, the difference in AC resistance between round wire and flat wire is much smaller than the difference in slot fill factor.

Myth 4: Ignoring Termination Quality. In high-frequency, high-current winding, the heat generated by the termination contact resistance may exceed the conductor’s skin loss. For flat wire terminations, soldering or crimping is recommended to ensure full-section continuity.


Conclusion

The effect of the skin on flat enamel-coated copper wire is fundamentally different from its effect on round wire. In a rectangular cross-section, the current distribution forms independent conductive bands on the four surfaces. This leads to a key conclusion: when the skin depth is much smaller than the flat wire thickness, thickening the wire is not beneficial for high-frequency resistance, while widening it remains effective.

However, this conclusion does not constitute a universal advantage for flat wires in high-frequency applications. While suppressing the skin effect, flat wire schemes shift the loss burden to the proximity effect—which increases quadratically with the number of effective conductive layers. Therefore, the actual losses of multi-layer flat wire winding may far exceed the skin effect of a single conductor. The correct engineering approach is to follow a geometric division of labor: low-frequency bands should prioritize slot full rate and cost, while high-frequency bands should prioritize layer reduction and widening, introducing geometric partitioning techniques when necessary.

The choice of enamel coating system cannot be downgraded in high-frequency applications. The temperature rise caused by the skin effect will compress the thermal margin of the enamel coating, while the stress concentration at the corners of the flat wire during winding places additional demands on the mechanical abrasion resistance of the enamel coating. The combination of these two factors usually requires the enamel type of high-frequency flat wires to be upgraded by one level.

In the manufacturing of high-frequency flat wires, three key process parameters need to be controlled: the radius of the corner fillet determines the resistance of the enamel coating during winding; the uniformity of the enamel coating thickness determines the resistance consistency along the entire winding length; and the corner coverage thickness and bonding strength determine the actual withstand voltage. The conductor can be pure copper or copper clad aluminum, and the enamel coating system covers polyurethane, polyester, polyester imide, and polyamide-imide.


Reference Standards

Standard Number Standard Name Coverage
IEC 60317-0-1 Winding wires — General requirements General technical specification for enamelled flat wire
IEC 60317-4 Polyesterimide enamelled flat copper wire EIW enamel system technical requirements
IEC 60317-13 Polyamide-imide enamelled flat copper wire AIW enamel system technical requirements
IEC 60851-3 Winding wires — Test methods — Mechanical properties Elongation, springback angle, abrasion tests
IEC 60034-1 Rotating electrical machines — Rating and performance Motor winding temperature rise and efficiency calculation
NEMA MW 1000-2018 Magnet wire standard Rectangular conductor dimensions and tolerance system
GB/T 6109.1 Enamelled round winding wires Enamel properties and general test method requirements
GB/T 6109.20 Polyesterimide enamelled flat copper wire EIW flat wire technical requirements
ASTM B33 Standard Specification for Enamelled Copper Wire for Electrical Magnet Wire Enamel thickness and withstand voltage tests
IEEE Std 1 IEEE Recommended Practice for Magnetic Materials for Power Transformers High-frequency magnetic component loss evaluation methods

Send Message