Ultra-thin Copper Foil for High-Frequency Transformers

High-frequency transformers are widely used in power electronics, new energy, communication equipment, medical devices, and other fields, with operating frequencies typically ranging from 20kHz to several hundred kHz. Compared to power frequency transformers, high-frequency transformers have significant advantages such as smaller size, lighter weight, and higher efficiency. As the core material for high-frequency transformer windings, the thickness accuracy, surface quality, and electrical performance of ultra-thin copper foil directly affect the conversion efficiency and reliability of the high-frequency transformer.

Copper Foil

I. Technical Characteristics of High-Frequency Transformers and Requirements for Ultra-thin Copper Foil

1.1 Operating Characteristics of High-Frequency Transformers

Compared to power frequency transformers, high-frequency transformers have the following significant characteristics:

  • High operating frequency, from 20kHz to several hundred kHz, with a wide frequency range
  • Small size and light weight; high frequency operation significantly reduces transformer size
  • High efficiency requirements; high-frequency loss is a major challenge
  • High heat dissipation requirements; high loss density per unit volume
  • EMI sensitivity; electromagnetic interference is a prominent issue

1.2 Skin Effect and Proximity Effect

High-frequency currents in conductors produce significant skin and proximity effects:

  • Skin depth: increases with frequency, and the current tends to converge towards the conductor surface
  • Effective conductive cross-sectional area is reduced, leading to increased AC resistance
  • Proximity effect: magnetic fields of adjacent conductors influence each other
  • Solutions: using thin copper foil or multi-strand fine wire winding

1.3 Core Considerations for Ultra-Thin Copper Foil Selection

  • Thickness accuracy: tolerance within ±0.01mm, ensures uniformity
  • Surface quality: Ra≤0.4μm, reduces surface roughness impact
  • Conductivity: IACS≥101%, reduces high-frequency losses
  • Width accuracy: tolerance within ±0.2mm, facilitates precision winding
  • Flexibility: adapts to complex shape winding

II. Specifications of Ultra-thin Copper Foil Materials

2.1 Recommended Grades and Characteristics

GradeCopper ContentConductivityThickness RangeTypical Application
C11000 (ETP)≥99.90%≥101% IACS0.05-0.3mmStandard high-frequency transformers
C10100 (OFC)≥99.99%≥101.5% IACS0.03-0.2mmHigh-performance high-frequency transformers
C10200 (TPA)≥99.95%≥101% IACS0.05-0.25mmPrecision high-frequency applications

2.2 Key Performance Parameters

Electrical Properties:

  • Conductivity: IACS ≥101% (annealed state)
  • Resistivity: 0.01724 Ω·mm²/m (20°C)
  • Skin depth: approximately 0.47mm at 20kHz; approximately 0.21mm at 100kHz

Geometric Dimensions:

  • Thickness range: 0.03-0.5mm (ultra-thin specifications)
  • Thickness tolerance: ±0.01mm (ultra-precision) or ±0.02mm (standard)
  • Width range: 3-200mm (precision specifications)
  • Width tolerance: ±0.2mm

Mechanical Properties:

  • Tensile strength: 200-280 MPa (annealed state)
  • Elongation: ≥15-25%
  • Hardness: 35-65 HV
  • Surface roughness: Ra ≤0.4μm (ultra-thin surface)

III. Special Process Requirements for High-Frequency Transformers

3.1 Selection of Ultra-Thin Copper Foil Thickness

Select appropriate copper foil thickness based on operating frequency:

Operating FrequencyRecommended ThicknessNotes
20-50kHz0.1-0.3mmSkin depth approximately 0.3-0.5mm
50-100kHz0.05-0.1mmSkin depth approximately 0.2-0.3mm
100-300kHz0.03-0.05mmSkin depth approximately 0.1-0.2mm
>300kHz≤0.03mmClose to or below skin depth

3.2 Winding Process Requirements

  • Tension control: Uniform tension, typically 5-10 N/mm²
  • Alignment accuracy: Edge alignment deviation ≤0.1mm
  • Interlayer insulation: Polyester film or insulating paper
  • Encapsulation: Epoxy resin encapsulation for fixation

3.3 Insulation Coordination

Insulation TypeRecommended MaterialThickness
Interlayer insulationPolyester film0.025-0.05mm
External insulationEpoxy resin1-3mm
Bushing insulationCeramic / PTFEAccording to voltage rating

IV. Industry Standards and Certification System

4.1 Applicable Standards

Standard SystemStandard NumberScope of Application
IECIEC 60325Copper foil for transformers
GBGB/T 5231Processed copper and copper alloys
ASTMASTM B372Copper foil for electronic applications
JISJIS H3100Copper and copper alloy foil strips

4.2 High-Frequency Application Related Standards

  • AEC-Q200: Automotive electronic component certification (if applicable)
  • UL Certification: Material safety certification
  • RoHS/REACH: Environmental compliance

V. Quality Inspection and Quality Control Points

5.1 Special Testing for Ultra-Thin Copper Foil

Test ItemTest MethodAcceptance Criteria
Thickness tolerancePrecision thickness gauge±0.01mm (ultra-precision)
Thickness uniformityMulti-point measurementFluctuation ≤0.01mm
Surface roughnessSurface roughness testerRa ≤0.4μm
Width toleranceCaliper measurement±0.2mm
ConductivityEddy current conductivity meterIACS ≥101%

5.2 High-Frequency Performance Related Testing

Test ItemTest MethodRequirements
DC resistanceFour-wire methodConforms to nominal value
AC resistanceLCR meter measurementConforms to design at 100kHz
Interlayer capacitanceLCR meter measurementConforms to design requirements

VI. Supplier Selection Recommendations

6.1 Core Capability Assessment

  • Ultra-thin production capability: Capable of producing 0.03-0.1mm ultra-thin copper foil
  • Thickness control accuracy: Within ±0.01mm
  • Surface treatment capability: Can provide ultra-smooth surface treatment
  • Width accuracy control: Within ±0.2mm

6.2 Technical Service Capability

  • Provide thickness uniformity test reports
  • Support small batch samples (from 10-50kg)
  • Non-standard customization (thickness, width, temper)
  • Timely technical support response

VII. Product Specifications (Reference)

GradeThickness (mm)Width (mm)TemperTensile Strength (MPa)Conductivity (IACS)
C110000.05-0.33-200O/H22200-280≥101%
C101000.03-0.23-150O/H22190-260≥101.5%
C102000.05-0.253-180O/H24195-265≥101%

Thickness tolerance: ±0.01mm (ultra-precision specifications)

Surface condition: Bright / Ultra-smooth

Packaging: Coil packaging + moisture-proof paper + foam shock absorption, suitable for air freight

Conclusion

The selection of ultra-thin copper foil for high-frequency transformers requires careful consideration of thickness accuracy, uniformity, and surface quality based on the operating frequency. When evaluating suppliers, it is recommended to focus on their ultra-thin copper foil production capabilities, thickness control accuracy, and high-frequency performance testing capabilities.

Our company has focused on exporting electrical wire and metal foil for 30 years, and can provide C11000/C10100/C10200 series ultra-thin copper foil for high-frequency transformers. Custom sizes are supported, and samples can be sent worldwide. Inquiries are welcome.

Contact Us:
Email: office@cnlpzz.com
WhatsApp: 0086-19337889070

Send Message

Get a tailored quote—fill out the request form and enjoy exclusive discounts!